CONSENT AGENDA REQUEST
|
Owners/Applicants:
|
Board of Supervisors
Meeting Date:
|
|
D. R. Horton, Inc. (Owner/Applicant) |
August 11, 2005 |
Staff Lead:
|
Department:
|
|
Holly Meade, Senior Planner |
Community Development
|
|
Magisterial District:
|
PIN: |
|
Scott |
7905-28-8368-000 |
Topic:
|
Ambler
Vale Subdivision (Lot 7): Preliminary Plat PPLT05-SC-022,
Scott District
|
|
Topic
Description:
|
|
The applicant is seeking Preliminary Plat approval to divide
approximately 5.23 acres into two (2) single-family
residential lots of ±3.31 and ±1.92 acres. These two (2)
divisions will exhaust all subdivision potential on the
property. Each property will be served by public water and
septic drainfield systems. |
|
Zoning/Acreage/Land Use:
|
|
The
±5.23-acre property
is zoned Residential (R-1). Adjacent properties are zoned
Residential (R-1) and used for residential purposes. |
|
Requested Action of the Board of Supervisors:
No action
is necessary, unless a majority of the Board wishes to
consider this preliminary subdivision application. On July
28, 2005, the Planning Commission voted to approve Ambler
Vale Subdivision (Lot 7) Preliminary Plat, subject to the
conditions noted below:
- The
Final Plat shall be in general conformance with the
Preliminary Plat entitled "Ambler Vale Subdivision (Lot
7)" dated February 23, 2005, signed by Robert L. Sporles
on June 7, 2005 and received in the Planning Office on
June 10, 2005, except as modified by these conditions.
This approval is for a maximum of two (2) residential
lots.
- The
County recommends that no below grade basements be
constructed on soils with high water table due to
wetness unless the foundation drainage system of the
structure is designed by a licensed professional
engineer to assure a dry basement and preclude wet yards
and recirculation of pumped or collected water. Unless,
in the opinion of the
|
|
County Engineer, the topography of the lot in relation to
the overlot-grading plan precludes grading the site to drain
the basement to daylight, all basements shall be designed to
gravity daylight without assistance from mechanical means.
All discharged water (mechanical or gravity) must be
conveyed to the subdivision stormwater collection system and
discharged through the stormwater management facilities.
Drainage easements, where necessary, shall be placed on the
final plat. A note shall be placed on the final plat
stating, “Basements are not recommended in mapping unit
16B. A basement in this mapping unit is subject to flooding
due to high seasonal water tables. Sump systems may run
continuously, leading to possible premature pump failure.”
-
Driveway culverts shall be designed to pass the 10-year
storm.
- Access
shall be provided to the well lot.
- The
plan and plat shall reference that no access shall be
allowed to Ambler Vale Drive (Private Street).
-
Entrances shall be constructed in accordance with PE-1
standard with minimum 15” x 30’ culvert pipe.
- The
house on Lot 7R shall be relocated outside of soil map
unit 48B.
-
Verification as to whether wetlands are present and
acquisition of any necessary permits shall be required
prior to final construction plan approval due to soils
type 16B, which is characterized as having hydric
inclusions.
- Map
units 48B and 440C shall be added to the Interpretive
Guide sections along with labeling the version used.
Use the most up-to-date version of the Interpretive
Guide.
|
|
Location: |
|
The property is located south of State Route 674 (Gray’s
Mill Road) off Ambler Court in the Ambler Vale Subdivision,
Scott Magisterial District.
Location Map

ATTACHMENT:
Preliminary Plat
|
|