The applicants are seeking Preliminary Plat approval to
divide approximately 44.84 acres into four (4) single-family
residential lots of ±2.00,
±2.00,
±2.00, and 38.1644
acres. The ±38.1644
acres, or residue, will be placed in a non-common open space
easement with the Final Plat. A copy of the Preliminary
Plat is located in Attachment 1.
The applicants are also seeking a waiver or modification of
Section 4-18 of the Subdivision Ordinance (Lot Shape), as it
pertains to Lots 1 & 2. Drain field constraints and the
required eighty-five (85%) percent non-common open space are
the given justification for the irregular shapes. The
applicant’s statement of justification is located in
Attachment 2.
Staff believes that the two circumstances listed in the
applicant’s Statement of Justification are valid reasons for
granting a waiver of Section 4-18 of the Subdivision
Ordinance. Also, the residue parcel or 38.16 acres will be
put in a non-common open space easement, which precludes
future subdivision of this parcel. Therefore, staff
supports the granting of the lot shape waiver.
The subject property is approximately 44.84 acres, which is
entirely zoned Rural Agricultural (RA). All adjacent
properties are also zoned Rural Agriculture (RA). Darrell’s
Run makes up the western edge of the subject property, with
significant acreage in the one hundred (100) year flood
plain, as determined by the Federal Emergency Management
Agency (FEMA). As shown on the following location map, the
property is situated on the east side on Heddings Road
(Route 794) north of its intersection with Sowego Road
(Route 611).
|
|
No action
is necessary, unless a majority of the Board wishes to
consider this preliminary subdivision application. On July
29, 2004, the Planning Commission voted to approve the Ifert
Property Preliminary Plat, subject to the conditions noted
below:
- The
Final Plat shall be in general conformance with the
Preliminary Plat entitled "Ifert Subdivision" dated
April 15, 2004, signed by Saundra D. O’Connell on 6-7-04
and received in the Planning Office on June 23, 2004,
except as modified by these conditions. This approval
is for a maximum of four (4) residential lots.
- The
conservation easement shall be delineated on the Final
Construction Plans.
-
Two-foot (2’) contour intervals shall be required with
the Final Construction Plan submission.
- A note
shall be placed on the Final Construction Plans and
Final Plat making potential lot owners aware of the
airstrip that is located on the adjacent property owned
by Mr. Robert Breeden (PIN 7940-85-4660-000). This
airstrip has an approved Special Exception by the
Fauquier County Board of Supervisors.
- Houses
shall not be placed in swales. The houses shall be
placed above the 10-year water surface elevation of the
swale.
- The
Storm Water Management (SWM) facilities shall be sized
to handle offsite water that drains to them.
- Based
on soils type, wetlands may exist in the area of the
proposed SWM facility. All applicable wetlands permits
shall be submitted with the first submission of the
Final Construction Plans. If wetlands do not exist, a
statement from a qualified professional shall be
required.
- The
County recommends that no below-grade basements be
constructed on soils with high water table due to
wetness unless the foundation drainage system of the
structure is designed by a licensed professional
engineer to assure a dry basement and preclude wet yards
and recirculation of pumped or collected water. Unless,
in the opinion of the County Engineer, the topography of
the lot in relation to the overlot-grading plan
precludes grading the site to drain the basement to
daylight, all basements shall be designed to gravity
daylight without assistance from mechanical means. All
discharged water (mechanical or gravity) must be
conveyed to the subdivision stormwater collection system
and discharged through the stormwater management
facilities. Drainage easements, where necessary, shall
be placed on the final plat. A note shall be placed on
the final plat stating, “Basements are not recommended
in mapping units 10A, 10B, 15B, 16B, 22B, 38B & 110A.
Basements in these mapping units are subject to flooding
due to high seasonal water tables. Sump systems may run
continuously, leading to possible premature pump
failure.”
- A
Virginia Certified Professional Soil Scientist (CPSS)
shall adjust the Type I Soil Map soil lines onto the
Final Construction Plan for lots 1-3. This shall be
done in the field and checked for any additional soils
information to be added to the Final Construction Plan.
-
Interpretive information from the Type I soil report for
each mapping unit shown on the above Final Construction
Plan shall be placed on the same sheet as the soil map.
Also, a Symbols Legend shall be placed on the Final
Construction Plan to identify spot symbols.
- This
final soil map shall be filed in the Building Department
to be used exclusively for obtaining soils information
for this proposed subdivision.
- Two
copies of this final soil map with CPSS signature shall
be submitted to the Soil Scientist Office before Final
Plat approval is made.
- These
statements under Home Sites and Road Construction
shall be placed on the same sheet as the final soils
map.
·
The County recommends that no below-grade
basements be constructed on soil mapping units 78A, 14B, and
62B, due to wetness, unless the foundation drainage system
of the structure is designed by a Virginia Licensed
Professional Engineer. The foundation drainlines should be
daylighted for gravity flow on all structures.
·
The following statement needs to be placed on
final soils map and E&S plans:
“PRIOR TO FINAL CONSTRUCTION
PLAN APPROVAL, IT SHALL BE AGREED THAT ALL DRAIN FIELD AREAS
ARE TO BE SURROUNDED BY SAFETY FENCING AND NO CONSTRUCTION
TRAFFIC SHALL CROSS NOR SHALL LAND DISTURBANCE OCCUR IN
THESE AREAS. THE FENCING OF THESE AREAS IS TO BE VERIFIED
BY COUNTY STAFF BEFORE THE ISSUANCE OF THE LAND DISTURBING
PERMIT.”
·
The following statement shall be placed on the
Final Construction Plan: “Foundations placed in soil mapping
units that show a moderate, high, or very high shrink-swell
potential in the most recent Interpretive Guide to the
Soils of Fauquier County, Virginia will require a
geotechnical evaluation in order to determine proper
design.”
14. A signature block shall be placed on this plat for the
CPSS to sign which states:
|
Preliminary Soils Information
Provided by the Fauquier County Soil Scientist
Office via a Type I Soil Map (1” = 400’) Dated April
12, 2004.
This Virginia Certified
Professional Soil Scientist has field reviewed and
adjusted the preliminary soil information onto the
final plat (1” = 50’) and certifies that this is the
Best Available Soils Information to Date for Lots 1
– 2.
Va. Certified Professional Soil
Scientist
DATE
CPSS #3401-___________ |
Attachment:
-
Preliminary
Plat
|